AURATON Virgo

Underfloor heating control strip (4 zones)

"AURATON Virgo (the successor to the AURATON 4D PRO). This wired control strip is designed for underfloor heating actuators and is intended for installation in electrical cabinets. The AURATON Virgo supports 4 heating zones, with the option to connect up to 3 AURATON actuators per zone. This allows for precise temperature control in different areas of your home. Additionally, each zone can be monitored using a wired AURATON temperature controller, providing complete control over your heating system. By installing it with AURATON Vela actuators, you're guaranteed a 10-year warranty on the control strip!

Are you interested in this product?

Where to buy

Heating device start delay function (approx. 3 min.)

4 heating zones (up to 3 AURATON actuators per zone)

Easy installation – the connections are equipped with pull-out clamps.

The AURATON wireless thermostat allows the user to monitor each heating zone

Control of the central heating circulation pump and the central heating furnace (potential-free contacts)

DIN rail mounting

Wired underfloor heating control strip with heating device control.

The AURATON Virgo features a heating device startup delay of approximately 3 minutes. This solution prevents sudden temperature spikes and ensures smooth system operation. The control strip allows for simultaneous voltage control of the central heating circulation pump and control of the central heating boiler via potential-free contacts.

How to instal a wired underfloor heating control strip?

The AURATON Virgo control strip is designed for DIN rail mounting, making it easy to integrate into existing installation systems. Thanks to connections equipped with removable clamps, installation is quick and simple. Before making cable connections, they can be easily disconnected, significantly simplifying the installation process. For more information on installation, please refer to the manual: AURATON Manuals.

Technical data

Power supply230V AC, 50Hz, 1.5W
Operating temperature range0 – 40°C
Working status signallingLEDs
Relay load capacitymax. 250V AC, max. 2 A (potential-free
contacts COM, NO, NC)
Head control output capacitymax. 30 W, up to 3 AURATON Vela actuators
per zone
Central heating pump output capacitymax. 200 W
Number of independently controlled heating zones4
Relay and pump start delayapprox. 3 minutes
Ingress protectionIP 20
Suggested mounting placemanifold box DIN rail

 